Valve Gate Control

<< Click to Display Table of Contents >>

Navigation:  Getting Started > Defining Injection Molding Components in SYNC > Runner >

Valve Gate Control

This section demonstrates how to set up valve gate control in hot runner attribute.

Select Hot Runner for runner attribute.

Check Valve Gate Control to enter valve gate control settings.

 

Users can trigger by Melt Front (melt front position) or Time (filling time).

 

Triggered by Time

Select the gate status, open or close, and set the delay time.

Click clip0104 to add a new control point.

Click clip0105 to save the modification of an existing control point.

Click clip0107 to delete an existing control point.

 

Triggered by Melt Front

Select a sketch point for trigger point, select the gate status, open or close, and set the delay time.

Click clip0104 to add a new control point.

Click clip0106 to save the modification of an existing control point.

Click clip0107 to delete an existing control point.