Please enable JavaScript to view this site.

Moldex3D Help 2021

Navigation: 4. Reference > 8. Error and Warning Messages

14. Material Check

Scroll Prev Top Next More

Error & Warning Messages - Material Check

Warning   291501

Symptom

Viscosity based on material parameters is not reasonable.

Warning   291502

Symptom

Viscosity is not in the range of data statistics.

Warning   291503

Symptom

Some viscosity parameter values are not reasonable.

Solution

Viscosity

Newtonian model: (Eta0)≤0

Power Law model: (B)≤0, (Tb)<0

Modified cross 1 model: (Taus, B)≤0, (Tb, D)<0

Modified cross 2 model: (Taus, B)≤0, (Tb, D)<0

Modified cross 3 model: (Taus, D1, D2, A2b)≤0, (D3, A1)<0

Carreau model: (Taus, B)≤0, (Tb, D)<0

Carreau-Yasuda model: (Taus, B, a)≤0, (D, Eta_infinity)<0

Herschel-Bulkely Cross model: (Taus, B, Tb)≤0, (D, Tauy0)<0

Herschel-Bulkely Cross (2) model: (Taus, D1, D2, A2b)≤0, (D3, A1, Tauy0)<0

Warning   291504

Symptom

Some viscosity parameter values are not in the range of data statistics.

Warning   291505

Symptom

The Viscosity model is unsupported in the Check function.

Warning   291601

Symptom

Specific volume based on material parameters is not reasonable.

Solution

Specific Volume

Modified Tait (2) model: For material considering constant Cp, parameter B5 has too different value compared to Cp peak temperature (Tc for specific heat)

Warning   291602

Symptom

Specific volume is not in the range of data statistics.

Solution

Specific Volume

Modified Tait (2) model: Parameter B5 has too different value compared to the suggested Cp peak temperature (Tc) based on material type.

Warning   291603

Symptom

Some PVT parameter values are not reasonable.

Warning   291604

Symptom

Some PVT parameter values are not in the range of data statistics.

Warning   291605

Symptom

Transition Temperature of PVT is not consistent with peak of Cp.

Warning   291606

Symptom

Transition temperature of PVT might be not reasonable.

Warning   291607

Symptom

The PVT model is unsupported in the Check function.

Warning   291701

Symptom

Specific Heat based on material parameters is not reasonable.

Warning   291702

Symptom

Specific Heat is not in the range of data statistics.

Warning   291703

Symptom

This version does not support "checking of Specific Heat coefficient".

Warning   291801

Symptom

Thermal conductivity based on material parameters is not reasonable.

Warning   291802

Symptom

Thermal conductivity is not in the range of data statistics.

Warning   291803

Symptom

This version does not support "checking of Thermal Conductivity coefficient".

Warning   291901

Symptom

Relaxation behavior might be not obviously enough.

Warning   291902

Symptom

Rubbery modulus might be too high.

Warning   291903

Symptom

Tf is suggested as Tg.

Warning   291904

Symptom

This version does not support "checking of Structure VE properties".

Warning   291904

Symptom

Transition Temperature of Solid VE is not consistent with Transition Temperature of PVT.

Warning   292121

Symptom

Temperature of Cp peak might be not reasonable.

Solution

Specific Heat

The temperature of Cp peak in variation (Tc) has too different value compared to the suggested based on material type (For example, PP = 120°C; HDPE = 110°C; PEEK = 295°C; PA6= 180°C; PA66= 235°C;
SPS= 230°C; POM= 145°C; PBT= 190°C;)

Warning   292131

Symptom

Freeze temperature might be not reasonable.

Solution

Process Condition

Freeze Temperature has an unreasonable value according to its difference to Glass transition temperature (Tg) or Crystalline temperature (Tc)

Warning   292132

Symptom

The freeze temperature should be greater or equal to temperature calculated by viscosity parameters.

Warning   292141

Symptom

Eject temperature might be not reasonable.

Solution

Process Condition

Ejection Temperature has an unreasonable value according to its difference to Glass transition temperature (Tg) or Crystalline temperature (Tc)

Warning   292142

Symptom

Ejection temperature is greater than freeze temperature.

Warning   292143

Symptom

Ejection temperature is greater than Tm or Tg.

Warning   292151

Symptom

Melt temperature is not in statistical range.

Warning   292152

Symptom

Minimum melt temperature should be greater than Tm at least 20 degree C.

Warning   292153

Symptom

Minimum melt temperature should be greater than Tg at least 50 degree C.

Warning   292201

Symptom

Elastic modulus is too great.

Warning   292202

Symptom

Elastic modulus is too small.

Warning   292203

Symptom

CLTE is too great.

Warning   292204

Symptom

CLTE is too small.

Warning   292205

Symptom

Elastic modulus E1 is not in reasonable range.

Warning   292206

Symptom

Elastic modulus E2 is not in reasonable range.

Warning   292207

Symptom

Elastic modulus E1 should be greater or equal to E2.

Warning   292208

Symptom

Poisson's ratio v23 is not in reasonable range.

Warning   292209

Symptom

Poisson's ratio of two directions (v12 & v23) shouldn't be equal.

Warning   292210

Symptom

Shear Modulus G is not in reasonable range.

Warning   292211

Symptom

CLTE a1 is not in reasonable range.

Warning   292212

Symptom

CLTE a2 is not in reasonable range.

Warning   292213

Symptom

CLTE a1 should be smaller or equal CLTE a2.

Warning   292214

Symptom

Fiber Length/Diameter is not in reasonable range.

Warning   292215

Symptom

Fiber weight percentage is not reasonable.

Warning   292216

Symptom

Polymer density is not in reasonable range.

Warning   292217

Symptom

Polymer Poisson's ratio is not in reasonable range.

Warning   292218

Symptom

Polymer modulus is not in reasonable range.

Warning   292219

Symptom

Polymer CLTE is not in reasonable range.

Warning   292220

Symptom

Fiber density is not in reasonable range.

Warning   292221

Symptom

Fiber modulus E1 is not in reasonable range.

Warning   292222

Symptom

Fiber modulus E2 is not in reasonable range.

Warning   292223

Symptom

Fiber modulus E1 should be greater or equal to E2.

Warning   292224

Symptom

Fiber Poisson's ratio is not in reasonable range.

Warning   292225

Symptom

Fiber shear modulus G is not in reasonable range.